Now Im having to turn my pool pump on and off manually. My pool pump timer is not working properly. The 240V or the T104 models have 5 brass screws (terminals) underneath the plastic insulator cover. },
I went to my houses main panel breaker and Flipped that breaker which leads to the pool panel breaker and replaced that breaker which goes straight to the timer. If its loose, grab a screwdriver and tighten it up. And Ive noticed lately that the ON is not functioning all the time. The terminals on the wires aren't tight. Your pool timer and pump will be on its own circuit and have a dedicated circuit breaker or GFCI (ground fault circuit interrupter). There is power; gears are moving. Its hard to give a fixed order for the steps you should take as it depends on what you found in the previous steps. Welcome to Pool Spa Outpost! Only perform this step if you are qualified. There could also be other mechanical reasons for this happening, such as a disconnect in the switch. Dont know what the issue is. My intermatic timer is not turning my pool pump on. When you flip the switch does it separate and reconnect the tabs? It is an ON tripper right? A qualified person would check there is power to the timer and then bypass the timer to see if the pump worked. I replaced a bad timer (90% sure I put the wires in the correct/same spots but there was one time when two wires got loose, so its possible I wired it wrong) and now it turns on and works, but the on/off switch doesnt work. Below is a breakdown of how to wire different Intermatic timer models. For extra safety, shut-off the Pool breaker on the main home panel too. Beyond the savings you'll make on reduced running costs, you'll also prolong the lifespan of your . The motor is running and I turn off using breaker in the electical box, I put a new timer in and does the same thing. However, since I did that the time clock stopped working I looked at the motor visual window and nothing is moving. Read Book Tork Trippers Manual Guide Pdf For Free Sea Kayaking The World Almanac Road Trippers' Guide to National Parks: 5,001 Things to Do, Learn, and See for Yourself Dream Trippers The Little Road Trip Handbook Technical Manual War Department Technical Manual Canadian Mining Journal. Do not remove the screws from the trippers. "image": {
Timer must be reset for current time after power outage. Im sure I hooked it up correctly but when running it gains a little over an hr of time every 24 hours. Go for it, a little maintenance expense. Why it always stop around 10pm by itself and not moving again? Timer not tripping pump on. You could spray some light lubricant like WD-40 or 3-in-1 oil onto the gears both for the motor and behind the dial. I currently manually turn it on and off. Also be sure that the front dial is engaged with the gear located behind the dial. how can I turn the time bar back down to the 6 oclock point so my timer will turn the lights on some how it is in the 2 oclock position an will not turn on automatically, Your email address will not be published. Hi Tanya, yes that sounds like it might be wired incorrectly, check the wiring diagram on the label, or if missing, you can find them online for your timer model. The most common pool timer used for inground pool pumps is the Intermatic time clock. Another time clock that you can plug your pump directly into, and then plug the timer into the outlet, is the 24-hr Timer https://www.intheswim.com/p/24-hour-pump-timer (currently we are out of stock, but you can find at any home or hardware store). Recently i just notice my T104R timer a bit noisier than usual. For some reason, whenever my timer hits the time its supposed to kick the pump on, it gets stuck at that time and the pump wont come on. I noticed one thing that the power from the breaker is going into the control panel. Miriam, I would check that the timer dogs are pushed fully onto the dial, and the dial is tight also check the screw for tightness in the center of the dial. Hi Rhomell, are you sure you got the correct trippers? So what you will need to do next is to troubleshoot your Intermatic timer with a few steps. Ive got the opposite problem than a lot of people. My pool cover is sinking into the pool because the two pillow have separated and have moved to the side. I have a inground pool with T10003RT4 control panel. Intermatic time clock motors can be replaced, but unless the time clock is brand new, its best to replace the entire Intermatic mechanism. And when switched on, power to the load terminals? Line is incoming, Load goes to the pump. Just installed a new timer. Or may be bent and not come together. Are the trippers slid all the way onto the dial fully? Tork pool timer dial, spins freely, not keeping Timer is not 100% identified. Generally the power goes from the breaker > Timeclock > pump, so that the power is always on to the clock. For Sale: 2 beds, 2 baths 1152 sq. Simply screw it back into place until its snug. Homes similar to 2425 Glenview Dr are listed between $725K to $2M at an average of $385 per square foot. These nuts are designed to provide a precise amount of clamping force and ensure proper alignment of the rear suspension, so reusing them may compromise the safety and performance of your vehicle. the timer was directly plugged into a gfci and the pump directly into the timer. First you want to make sure there is actually power getting from the power board to the timer itself. Does the manual lever stay in the on position always? Reasons Why Pool Timers Stop Working 1. Should it still not work, I suspect a motor failure for the clock. Thank you so much. Dead as a door nail. Take them off and inspect them. The clock will also be missing 3-hours of time, so will need to be reset to the current time. document.getElementById( "ak_js_1" ).setAttribute( "value", ( new Date() ).getTime() ); Professional plumber and home repairs expert, How To Remove Broken Hayward Super Pump Drain Plugs. On occasion the two points that are used for setting the ON and OFF times for the pool pump get damaged or loosen. Karl, good question. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and . "dateModified": "1/10/2020",
Slide it around the pool timer dial to the correct start time and re-tighten it. Any thoughts before I run out to replace it? So either the tripper is broken (or installed out of alignment) or the tab (s) on the on/off switch are broken. i would like to use a timer but am now afraid to try another. If the motor or wires are faulty in your Intermatic time clock, its time to replace the mechanism. Any ideas? If no damage is seen and the wires are intact, and the motor gears are not turning, and you find nothing stuck in the gears (sand, insects, any obstruction), and some spray WD-40 on the gears and a little push from a small flathead screwdriver does not help then, you can assume that the motor is dead, at which point you can replace the motor itself with the exact replacement, or replace the entire clock. Sometimes those are looped back to the control box. Should I go ahead and spray it anyway? i have an oval pool that is closed for the winter but there ha been a problem. Look to see if the clock is set to the correct time. I replaced my pool timer a couple of months ago with a Tork 1109A mechanical 240v timer. If there is power going to the timer and the timer appears to be working but the pump isnt turning on and off, then youll need to check the pump. Electricity is dangerous and can kill you if you dont know what youre doing. About 1-2 years ago I swapped out this unit because it was sticking and not engaging when it was supposed to. Does the tripper work on other areas of the clock, like near the off tripper? Theres an issue with the wiring between the circuit breaker and the timer. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide"
If you cant, is the manual switch stuck or jammed? See the next section in this article for that. Can I spray the timer while there is electricity going in the timer box? The same happens prior to the timer reaching the off tripper. The tabs on the back of the timer may have fused together, or the tabs on the stationary switch at the rear of the motor, from a power surge. Start with the easy checks. Can I wire this timer to an outlet or should I search for another solution? Check out our online selection of new Intermatic timer clocks at InTheSwim.com! Take them off and inspect them and look for twists in them. Jul 20, 2021. Repeat the process for the "on" pin. It worked for a day but the day after it didnt work. If you need to set the time, you will need to take two fingers and slightly pull the wheel towards you and away from the back of the timer box. Help! Once you remove the water, you can use your pool brush on a pole, to gently push the pillows back to the center. See the wirig diagram in the owners manual here: https://www.intheswim.com/images/PDFs/E2412_Owners_Manual.pdf Clock motor power, as shown in the wiring diagram, comes from terminal 1 and also terminal 3. Also be sure that the ON dog is not actually an OFF dog, and that it is tightly secured to the dial edge and pushed all the way onto the dial, and straight. You can turn off Freeze protection and it should stop, or replace the probe if faulty. We cover T101, T103 and T104 models of mechanical pool timers. The old "off" tripper was fractionally bent. There are 2 main facets to setting the mechanical timer for a pool pump, setting the time, and setting the on/off trippers. Stupid third question, but does the ON tripper say ON? Hotels near Time Tripper, Arcueil on Tripadvisor: Find 9,014 traveller reviews, 1,228 candid photos, and prices for 2,893 hotels near Time Tripper in Arcueil, France. That way I could schedule the pump once again. I have a PF1112T. Hi Davy, Any advice? There are simply things you can do yourself like adjust the timer pins and set the clock on the timer. Hi Derrick, first try to reposition the timer tripper, making sure it is all the way on the dial. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
make sure it hasnt tripped and is switched on. but ythe costs for T104 models vary greatlyHave ahayward 1 1/2 horsepower pump inground pool in Fl. I have three outlets going out one to the pump , one for the salt system and one for the GFCI outlet. Step 3 I had a power surge last night ( funny as there was no storms here ) and now my intermatic T104M timer doesnt work anymore. Pool and Spa Expert: Mike_G2010 With the switch up it is in Auto mode. Hi Catherine, turning it on manually should not have damaged anything, so go easy on yourself It might have just been time to go. Spray WD-40 or any kind of lubricant onto the manual lever to loosen it. how do I check the manual over ride switch to see if it is off? ), you should be able to discern if this is the problem, which could mean a new clock. Turn in either direction and align the exact time-of-day on . I looked to see if the gears on the timer are running. You can always call us at 815-675-7000 M-F 8am-4:30pm CST and speak with a live technician. Ill do the same. Check that the breaker is firmly pushed onto the bar, and is not loose. I visually checked the clock motor and it was good. Gently tighten the screws to securely hold the dogs in place. My intermatic timer is about two years old as well. You should always be able to switch your pump on and off manually at the timer. I have Model T40004RTe. This will cause issues such as the pump not switching on or off to the pump turning on or off at incorrect times. 1100 Juanita St , Austin, TX 78704-5351 is a single-family home listed for-sale at $2,649,000. If you look closely, you should be able to discern if this is the problem, which could mean a new clock. It is twisted clockwise or counterclockwise until the correct current time lines up with the "Time" marker, which points directly downward at all times while the clock dial constantly turns. Posted by 4 years ago. If the trippers are set for on and off pump function and nothing is working, reset the time and trippers. Check the motor, and be sure the label is not printed 50 hz. Followed all directions and even watched YouTube troubleshooting videos. Metal Trippers Step 1 Look on the front of the metal trippers to find the one identified as "Off" and the one labeled "On." Step 2 Loosen the screws on the face of the metal trippers. This product can be controlled with your voice through Alexa-enabled devices such as Amazon Echo and Amazon Tap. Check to be sure that the yellow time dial gear on the back is engaged with the connecting gear, and pushed all the way in. No Power to the Timer Having no power to your pool timer is a common problem and will occur because of three reasons: The Circuit Breaker has tripped. You off course will want to adjust one time pin at a time. Now The ice and snow have melted and the cover is getting in deeper. That was probably what burned the plug. Your timer is on a 24-hour cycle. No luck. I have an Intermatic 277/208v T104 timer controlling two 60Hz 120v outdoor lighting circuits. The timer appears to be working fine (keeps time). Can A intermatic timer for a pool be lubricated I have duel timers for a low and high speed jandy pumpIt seems it might be a little louder on the fast speed side. It is still moving and it will trip off but not on. If thats all ok, shut off breaker and depress tab at the top, to release the mechanism from the box, and look at the copper tabs in the back. Make sure the middle time pointer is tight. David, check the wiring, the power in and power out wires may be reversed. "keywords": "",
The 2,810 sq. 240V out of the timeclock (Load/Load terminals) and nothing on the motor terminal board? If you do have voltage either the timer isnt switching the power to the pump or theres an issue with the pump itself or the wiring between the pump and the timer. Any other thoughts? PF1202T Freeze Protection Control Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Is there anything else I can do or do I need to get a new one? Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer 4. Voltage is 243, frequency is 60hz. The pool was running on a timer. Gears are moving , clock is seated correctly and everything is wired per diagram now that pool season is here I have to manually turn my pool on and off at the timer . Hi John, the trip mechanism on the clock, the switch, could be worn to the point where the tripper does not make good contact. Then after a bit, the pump restarts. Use a power meter set on AC volts to verify the power is off, before handling the timer mechanism. But of the timer itself is bad you will need a licensed electrician to change the timer for you. "@type": "ImageObject",
OPEN TODAY, 12PM TO 3PM. To use an analog timer, you simply need to set when you want the timer to be on and off using trippers. For example, sometimes you can see a burnt wire or sometimes it may be as simple as the circuit breaker has been tripped. "height": "219",
Is there a control board, PCB in the panel that could have problems? "name": "In The Swim",
220V clocks have 5 terminals, 110V clocks have 3 terminals. Hi DavyI just installed a new timer after being told by the pool inspector that the old one was dead. Intermatic time clocks are the workhorse of your pool equipment collection, and oftentimes outlive the equipment they control. I can turn the pool pump on via the manual power lever thats located at 5 O clock on the timer. 2,767 Sq. Partially loosen the screw that holds the "off" pin in place. Is it possible to do this by loosening the timer screw a bit? "@type": "Organization",
Shannon, compare the wiring to the diagram for Line and Load (line is power coming in, Load is power out to your pump). As an Amazon Associate we earn from qualifying purchases. Sometimes old power wires split or short-out. If you have both pins take notice of there position and then come back in a few hours and see if they have changed from the spot they were in when you last looked. Check out the wiring diagram that comes with a new timer, or is printed on the door of the timer box. The problem I am having is the timer clock moves correctly, but when it gets to the ON or OFF mark it stops and does not make the switch turn ON or OFF. Should You Get a Pool Pump Timer? "wordCount": "1259",
Hi, if you have a variable speed pump, you do not need to use the external timer anymore, but should program with the on-board pump timer. A timer replacement would be required. Now remove the terminal cover on the timer. Does this give you a better idea of the problem? More. Or might find something else. Perhaps you had a power outage during the night? The time is in my workshop and i normally sit next to it all the time so i know its noisier but its still working fine. Step 1 - Check that Timer is Functional Locate the two timer pins on your timer. Thanks. Date Listed: 18/02/2023; . not sure what is the problem. PF1202T Freeze Protection Control Parts - INYOPools.com Home Pool Parts Time Clock & Control Parts PF1202T Freeze Protection Control Free Shipping on all Orders over $49! Wont work manually or by timer function. If your timer pins have not moved that means there is no power to the timer or the timer has failed and need to be replaced or possible manual over ride switch for the timer is off. There are many reasons why your pool timer may not be working. The BN-LINK compact outdoor mechanical pool pump timer is programmable in 15-minute intervals with 48 setting options in a 24 hours period. Also be careful not to loosen the timer pins to much or they could fall off the timer wheel and onto the ground. I had a thunderstorm last night and my power went off for like 3 hours. This product is certified by Amazon to work with Alexa. Perhaps bad wiring or a bad breaker is to blame. My clock seems to work but but the on and off switch does not turn on the pool pump. I have an intermatic T20004R and my timer is working because it is keeping the correct time. So if you see the 10am behind the time marker, this means that the timer has the current time of 10am. I bought a new timer and replace the T104 timer clock. Hi Larry, if you can see the motor gears turning in the visual motor check, you may just need some lubrication added to the tripper mechanism. Could be small bugs, or dirt, or both causing the problem. Another thing you will need to troubleshoot and check is the circuit breaker for your pool timer. Please let me know if you find the solution! Give it a little squirt of WD-40 or similar lubricant. "caption": "In The Swim Blog"
Is the timer repairable, or should I just install a new one? Do you have an answer to why my pump wont turn off or on? So I connected all leads as on the directions and the clock and on off manual switch working.Not sure if timer was never connected or someone disconnected it. Or if power is interrupted to the pool pad, for some reason, maybe breakers flipped off for some electrical work? Required fields are marked *. You can replace it but its really just easier to replace the entire mechanism. Many thanks! Here are some pictures. Did somthing else maybe burnt out or what is a good troubleshooting I can do before I call an electrician. "url": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
Some white lithium grease on the switch can help in some cases. Check the wire connections to be sure they are tight, and look for any burnt wires. Hi Casey, perhaps the cord or wires are broken? I replaced the pump and still nothing is moving. "headline": "Intermatic Pool Timer Troubleshooting",
If not, that sounds like a weak/bad motor. I have replaced the trippers, but the problem persists. The instructions say THIS TIMER IS NOT TO BE USED AS A POWER DISCONNECT. Since it came out of the box today, it probably is not trash in the gears.It seems the plastic gears and/or the coil in the clock mechanism are not strong enough to engage the on/off points or not for long. 20 Reasons Why Pool Pumps Lose Pressure (and what to do), 25 Ways to Keep Ducks, Geese & Birds Out of Pool. To check this, try to pull out the clock dial and then move it to the correct time and press it back down again. If you are not sure if your timer is working or not you will first need to know if its even operational. But if your circuit breaker is in the on position and your pool timer clock is not rotating and the timer is not working then you will need to call a licensed electrician to replace the timer. My timer works good it turns on and off when I set the time. NEW CONSTRUCTION. Any suggestions on how to troubleshoot? The timer not working is for the pump. Yes, seen that before! Im going to try inspecting the back of the timer to see if a wire go knocked loose or something. Jun 3, 2013, 10:07 AM You will have ON trippers and OFF trippers, You can place an ON at Noon, and OFF at 1:00 for 1 hours operation, If you manually turned it back on at 3:00, it would stay on until the next OFF tripper (1:00). DEWENWILS Pool Pump Timer, Outdoor Smart Wi-Fi Box, Heavy Duty 40A 120-277 VAC 2HP Wireless Controller Timer for Pool, Water Heater, Compatible with Smart Phone, Alexa, Google Assistant, UL Listed. Thanks for any help you can give. by pool co. , so wondered about the cost. I noticed that they had stopped. "author": {
Thank you for choosing Intermatic! I see that the Intermatic WG1573-10D Replacement 208-277 VAC, 60 Hz Motor, is compatible with For use with T102, T104 and WH40 clocks by Intermatic. Ive got a weak pump battery so every time the mechanism shuts off it looses time. I need to replace a timer for my pool vacuum. Timer not tripping pump on. I can manually turn it on with the lever at the bottom. The yellow clock face should sit down in the timer. You can turn that yellow dial by hand CW to see if the trippers hit the off and on switch and to set the time on it. However, the timer will stop around 10pm everyday and will not continue moving forward again. Lately, the timer mechanism on my old T104R does not move. I have the pool timer with the red teeth that you pop up or down depending on when you want the pool to run. It just stays at that time. Sometimes the trippers get loose or damaged. Clock wont move, gear dont move at all. The other gears are not and the pump will not turn on or off unless done manually. {
My timer clock does not run and the manual on off switch does not turn off the pump motor. JACUSTOMER-hlvgjzll- : I have just sprayed WD-40 on the switch coils that move the lever that the trippers hit. These clocks determine when your pool pump turns on, and how long it runs. Phil. Move the switch and see that they separate when off, and come together when on. Hi Jeremy, I would try to pull the unit out and clean it well with compressed air and then spray with WD-40 and see if that helps. Hi Phil, usually the OFF dog may not be fully pushed onto the dial, or if you examine it closely, it might be worn. Proceed to step 4 to check the timer itself. The Intermatic Model T104R Timer that turns on and off the motor on my pool recently, about two or three times week, trips my GFCI requiring me to reset it which has been increasing very hard to to reset. Sound right? Off flipper always works. Now try to jiggle it on and off. Look at the copper tabs on the back and observe the action as you flip the switch manually on and off. Any guidance on how to fix this? If you look closely (with a flashlight and your glasses! Hi Matthew T104 can only turn one pump on and off. Leave the paper inside your timer box so that you do not mistakenly misplace it. It stays on until I turn off the circuit breaker. Replace them if they appear to be bent. Also check that the motor number is compatible with your clock model. It should loosen up after a few goes when the grease and gunt dissolve. Manual switch works my aerator. How do you know if your pool timer is bad? Did you try to flip the switch of the timeclock? Sometimes its way quick just to replace it rather than spend hours troubleshooting. I have the PF1202T timer on my pool. However, intermittently after the ON tripper switches pump on the pump will stop. we purchased the house 5 years ago so not sure how old the timer is? View community ranking In the Top 5% of largest communities on Reddit. Did the power recently go out or has the circuit breaker tripped? Inside, the 1 gear on the right side can be removed to access a metal bar. "publisher": {
To adjust the time you will first want to look for the time bar that is mounted in the middle of the timer wheel. All Rights Reserved. Terry, unusual but check all connections, making sure that bare wire is tightly contacting the terminal screw plates. A timer that switches on and off at the wrong times usually occurs after a power outage. Any suggestions as to how to test clock feed? Hi Sam, check that the dial is not warped or bent, the yellow clock dial. Push down on the timers until they snap into place. Not two OFF trippers? Please advise. Some of the replacement motors make it past quality control with the incorrect gear setup. Save my name, email, and website in this browser for the next time I comment. Confused. (For outside light timer) The one before was original to the house & I had no trouble. When the trippers are done up, you shouldnt be able to move them with your hands. Then remove the mechanism by pressing the clip at the top of the timer box. Video of the Day Trippers Found the answer. Is that a faulty motor? If the timer clock is not turning on your pool pump timer, its either the timer itself has a fault or theres no power to the timer. Yes, likely a short to ground. "contentUrl": "https://x1.adis.ws/v1/media/graphics/i/lesl/its-logo-wide",
I went to the control panel and saw that the timer needle stopped just after the start pointer. 120Volt Tork 1101 timers can be fixed with repair parts. Depends maybe on what it is getting stuck on, or what is catching the tripper, and are the motor gears still turning when it gets stuck? Today is the second day that I have had to turn it on manually. If I manually push the lever, it moves without much pressure. If the motor gears are not turning, check the wire tightness (Breaker off first), and depress the tab at top to inspect the rear of the mechanism, to see if anything looks funny back there. Reset the clock on the timer to the correct time to get it back to the desired on/off times. I have the same issue currently, and it makes no sense to me so far. "width": "611",
The back of the timer dog has a tab that flips the switch, check the alignment of both, the dog may not be contacting the switch with enough surface to flip it on? It loses about 1.5 to 2 hours per day without any outages. I have a intermatic T101 and the clock doesnt move I replaced the old one due to burned out motor . View more property details, sales history and Zestimate data on Zillow. . Did you find the issue? Turn the metal bar until it contacts one of two plastic side tabs. it could also be a failing breaker, but that would be a last resort. Terminal A (farthest to the left side) is not connected to anything. In this case its likely the On/Off trippers, loose wiring, the clock face not being located correctly or a faulty pump. Second thing to check is the dial bent or warped, in that area where the on tripper is? When I put the new one on, the trippers do not work. The timer motor cover (the oval silver box with the printing) can be pried off with a sharp screwdriver. The dial turns, but when it gets to the trippers, both now, the dial stops & there is no sound the gears are working I am not an electrician but I can do small repairs. In most cases like this, replacing the trippers is the solution. Or other advice or explanation. The time does not advance after resetting. BUILT BY HAND IN QUEENS, NYC. Grab it, pull it towards you, move it around then place it back down. They are little ants that just came. I called Intermatic and there is nothing you can do except check it every time you have a power loss. Other problems causing this could be the yellow clock dial isnt located correctly, wiring is loose, the gears are stripped, damaged or partially jammed or even the clock motor. Turn on / off manually work fine, but The clock gears still not moving. You can replace the entire mechanism or the gears. Since you have another switch in between the breaker and clock, the breaker will lose power when the switch is turned off. Any suggestions? Tighten down all brass screws securely, to hold all wires firmly in place. Once you figure out what is wrong with the timer, you may be able to do the repair yourself or might have to hire an electrician to come and replace the timer for you. There are many reasons why your pool timer may not be working. The most common pool timer used for inground pool pumps is the Intermatic time clock. Hi, hope you are doing well. Hi Jere, that could be the timer motor failing. But the next morning it wont engage by itself again, it seems it sticks when getting to the point its supposed to flip on. Is it keeping time normally? You can replace the timer motor only, or the entire clock, both fairly easy to swap out. Check that dial is not warped. It started lagging again a week or so ago. Any suggestions? Richard, pull the mechanism out of the box by releasing the clip at the top and inspect the copper strips and pads on the rear.
Ducharme Architecture,
Footy Express Timetable 2021,
Articles P
You must point pleasant school district jobs to post a comment.